NMTI 2 - current converter AC
NMTI 2 - Two-input transducer of rms values of electric current
A modern multipurpose quantity-to-current loop converter designed for installation in switchboards.
To order the devices as contact us at: mcu@metra.cz
NMTI 2 - Two-input transducer of rms values of electric current
The NMTI 2 is a two-input transducer with two independent analogous outputs. Both of the outputs are electrically isolated from the outputs, from the power circuits and from each other, so that one NMTI 2 transducer is able to replace two common current transducers. In this way a significant savings of installation space can be achieved.
ENGINEERING PARAMETERS
- powering voltage 20V to 260V DC or AC 50/60 Hz
- power consumption 1.5W at fully loaded outputs
- number of current measuring inputs 2
- rated input current In selectable within 1A to 5A range
- input current range 0 to 1.2 In
- accuracy of current measurement 0.2 % In
- input overload capacity, permanently 1.2 In
short-time 20 x In /one second
- analogous outputs 2
- current type 0...20mA; 4...20 mA
or on order 0…x mA (x= 5 to 20 mA)
- voltage type 0...10 V
or on order 0…x V (x= 1 to 10 V)
There is a galvanic interconnection between the GNDA and GNDB ground terminals established internally in the transducer!
- settling time after the connection of power supply 1 minute
- operating temperature range -25 to +70°C
- error caused by ambient temperature
no more than ±0,1%/10°C, as per the requirements of ČSN EN 606 88 standard, to apply for the temperature range of –25°C to +55°C (+ 0.2% of additive error caused by ambient temperature ranging from +55°C to +80°C)
- permitted output load ranges
- voltage output Ru higher than Uan /8mA
- current output Ri loop resistance less than 10V/Ian
- dielectric strength (as per ČSN EN 61010-1)
- inputs as against the outputs and power circuits 3700V; 50Hz/1min
- in between the inputs 1000 V; 50 Hz/1min
- weight no more than 150g
- dimensions 101x114x24 mm
- working position arbitrary
- protection degree IP 20
- electromagnetic compatibility radiation: as per ČSN EN 55011-B
- immunity: as per ČSN EN 6100-6-2 ed.3
Safety according to ČSN EN 61010 – 1 standard: equipment of class II, overvoltage category III after having become a part of the installation (highest voltage against the earth: 300Vrms), pollution degree 2